Supply Water Leakage Protection System WLP-1
|
Run-in function:
Following adjustment of the clock, the WLP-1 may undertake
full or partial automatic run-in according to the actual water
consumption pattern. The run-in may be set to last from
1 day to 1 year; following run-in the system will calculate
required monitoring parameters and reinstate leakage
monitoring for the mechanisms that were run-in.
Registration:
WLP-1 continuously logs events, system changes, key variables and
consumption characteristics for presentation in the display
or via remote communication.
BMS Attachment:
WLP-1 has outputs for repetition of flow meter impulses to a BMS,
with optional selectable scaling. Leakage alarms etc. may be signalled
to the BMS with the uncommitted relay outputs.
Alarm Connection:
The system accepts signals from BMS or Burglar Alarm Systems for phase switching,
and from Fire Alarm Systems or Fire Cabinets for forcing open the cut-off valve.
Flow Meter Options
In addition to the standard Ultrasonic flow meters, the WLP-1 may be supplied with
a range of mechanical or magneto-inductive flow meters to suit special requirements.
|
System extensions
Point monitoring (Opt. V):
WLP-1 accommodates up to eight liquid sensors LS-X for extra
protection of specific exposed or vulnerable locations.
Multi Leakage Protection (opt. N):
WLP-1 accommodates up to four flow meters, thus permitting simultaneous
leakage monitoring of up to four separate branches.
Hereby installations can be segmented, e.g. cold supply water/fire cabinets/warm supply water/grey water
for optimum safety and convenience. Be sure to obtain specific dimensioning quotation and reference number.
Circulating Warm Supply Water
Using the BW meter attachment, meters for warm water Flow and Circulation can be
connected, whereby the WLP-1 can monitor the warm water consumption, even where
monitoring at the calorifier cold water intake is impractical.
Remote Monitoring type WM
When connecting a GSM modem the
water consumption can be remotely monitored using System WM.
By connection of a serial device server, the water consumption may be monitored on a local network using System WM.
Left: WLP-1 can also be supplied with mechanical flow meters.
Illustration depicts system WLP-1-B6-V1.
|
|
WLP-1 Systems with Ultrasonic Flow Meters
System |
Capacity and pressure loss |
Dimensions |
Nom. Cap. Qn (m³/h) |
ΣΔp@Qn |
Equivalent Kvs (m³/h) |
(mwc) |
(kPa) |
Flow meter |
Cutoff valve |
WLP-1-BK2,5-V1 |
2,5 |
0,42 |
4,2 |
12,2 |
¾" x 190 mm |
¾" x 80 mm |
WLP-1-BK4-V1 |
4,0 |
0,93 |
9,3 |
13,2 |
1" x 260 mm |
1" x 90 mm |
WLP-1-BK6,3-V1 |
6,3 |
2,24 |
22,4 |
13,3 |
1" x 260 mm |
1¼" x 110 mm |
WLP-1-BK10-V1 |
10 |
0,65 |
6,5 |
39,2 |
1½" x 300 mm |
1½" x 120 |
WLP-1-BK16-V1 |
16 |
1,63 |
16,3 |
39,6 |
DN50 x 270 mm |
2" x 140 mm |
WLP-1-BK25-V1 |
25 |
0,71 |
7,1 |
94 |
DN65 x 300 mm |
DN65 x 46 mm |
WLP-1-BK40-V1 |
40 |
0,6 |
6,0 |
163 |
DN80 x 300 mm |
DN80 x 46 mm |
|